Header menu link for other important links
X
Heat transfer, friction factor and thermal performance of three sides artificially roughened solar air heaters
, B.N. Prasad, L. Prasad
Published in Elsevier Ltd
2016
Volume: 130
   
Pages: 46 - 59
Abstract
This paper presents the experimental results on heat transfer, friction factor and thermal performance of a novel type of three sides artificially roughened and glass covered solar air heater under fully developed turbulent flow conditions. The results on heat transfer and friction factor compare well with analytical values (Prasad et al., 2014), for the range of the values of operating parameters. Such solar air heaters have higher value of heat transfer coefficient than those of one side artificially roughened solar air heaters in the range of 21-78% for the same values of operating parameters. The values of performance parameters, FRUL and FR(τα) and consequently those of FR and F', have been found to be superior to those of one side roughened solar air heaters. Thermal performance equations in terms of the performance parameters have been derived. Enhancement of about 40-48% in thermal performance over those of one side artificially roughened solar air heaters has been achieved. © 2016 Elsevier Ltd.
About the journal
JournalData powered by TypesetSolar Energy
PublisherData powered by TypesetElsevier Ltd
ISSN0038092X